GW Instek GPS-3030DD 90W Single-Output Linear DC Power Supply

GW Instek

Compare

The GW Instek GPS-3030DD single-output linear DC power supply unit provides a constant source of DC voltage and current for powering and testing electronic devices.

259.00

  • Linear power supply unit provides a constant source of DC voltage and current for powering and testing electronic devices in research and development, production, and laboratory applications
  • One output provides an adjustable voltage of up to 30VDC or current up to 3 amp
  • Potentiometers on front panel provide fine and coarse adjustment of voltage and current output
  • Dual digital LED screens show voltage and current readings simultaneously and are readable in low light
  • Continuous or dynamic internal load selection for applications such as pulsed current

 

Please contact the office for details on accessories

Brand

GWInstek PPH-1503 Datasheet

  • DC GENERALMEASUREMENT TIME CHOICES0.01 ~ 10PLC1,0.01PLC/step
    AVERAGE READINGS1~10
    TYPICAL READING TIME2,331ms
    DC VOLTAGE OUTPUT
    (23℃±5℃)
    OUTPUT VOLTAGE0~15V
    OUTPUT ACCURACY± (0.05%+10mV)
    PROGRAMMING RESOLUTION2.5mV
    READBACK ACCURACY3± (0.05%+3mV)
    READBACK RESOLUTION1mV
    OUTPUT VOLTAGE RISING TIME0.15ms (10% ~ 90%)
    OUTPUT VOLTAGE FALLING TIME0.65ms (90% ~ 10%)
    LOAD REGULATION0.01%+2mV
    LINE REGULATION0.5mV
    STABILITY40.01%+0.5mV
    RECOVERY TIME(1000%LOAD CHANGE)
    RIPPLE AND NOISE51mV rms(0~1MHz)
    8mVpp(20Hz~ 20MHz)
    DC CURRENT
    (23℃±5℃)
    OUTPUT CURRENT0 ~ 5A (0 ~ 9V)
    0 ~ 3A (9 ~ 15V)
    SOURCE COMPLIANCE ACCURACY±(0.16%+5mA)
    PROGRAMMED SOURCE RESOLUTION1.25mA
    READBACK ACCURACY35A range: ±(0.2%+400uA)
    5mA range: ±(0.2%+1uA)
     READBACK RESOLUTION5A range: 100uA
    5mA range: 0.1uA
    CURRENT SINK CAPACITY0 ~ 5V: 2A
    5 ~ 15V:(2A derate 0.1A)/V
    LOAD REGULATION0.01%+1mA
    LINE REGULATION0.5mA
    STABILITY40.01%+50uA
    DVMINPUT VOLTAGE RANGE0 ~ 20VDC
    INPUT IMPEDANCE10Ω
    MAXIMUM INPUT VOLTAGE-3V, +22V
    READING ACCURACY3± (0.05%+3mV)
    READING RESOLUTION1mV
    PULSE CURRENT MEASUREMENTTRIGGER LEVEL5mA ~ 5A, 5mA/step
    HIGH TIME/LOW TIME/AVERAGE TIME33.3us to 833ms, 33.3us/step
    TRIGGER DELAY0 ~ 100ms,10us/steps
    AVERAGE READINGS1 ~ 100
    LONG INTEGRATION PULSE TIMEOUT1S ~ 63S
    LONG INTEGRATION MEASUREMENT TIME850ms(60Hz)/840ms(50Hz) ~ 60s,or AUTO time 16.7ms/steps(60Hz), 20ms/steps(50Hz)
    LONG INTEGRATION TRIGGER MODERising, Falling, Neither
    OVPOVP RANGEOFF,ON (0 ~ 15.2V)
    RESOLUTION10mV
    ACCURACY50mV
    OthersPROGRAMMINGIEEE-488.2(SCPI)
    USER_DEFINABLE POWER_UP STATES5 sets
    REAR PANEL CONNECTOR8Pin:output*4, sense*2, DVM*2
    TEMPERATURE COEFFICIENT0.1* specification/ ˚C
    POWER CONSUMPTION150VA
    REMOTE/LOCATION CONNECTORUSB/GPIB/LAN
    RELAY CONTROL CONNECTOR150mA/15V  5Voutput, 100mA
    InsulationChassis and Terminal20MΩ or above (DC 500V)
    Chassis and AC cord30MΩ or above (DC 500V)
    Operation EnvironmentIndoor use, Altitude: ≤ 2000m
    Ambient temperature: 0 ~ 40°C
    Relative humidity: ≤ 80%Installation category: II, Pollution degree: 2
    STORAGE EnvironmentTEMPERATURE: -20˚C  ~ 70˚C
    HUMIDITY: < 80%
    INPUT POWER90-264VAC, 50/60Hz 6
    AccessoriesCD 8cmUser manual x1, Quick Start manual x1
    Test lead GTL-117 x 1, GTL-203A x 1, GTL-204A x 1
    Dimensions222 (W) x 86 (H) x 363 (D) mm
    WeightApprox. 4.2kg
     Remarks
    1. PLC=PowerLineCycle, 1PLC = 16.7ms for 60Hz operation, 20ms for 50Hz operation;
    2. Display OFF, Speed includes measirement and binary data transfer out of GPIB;
    3. PLC=1;
    4. STABILITY:Following 15 minute warm-up, the change in output over 8 hours under ambient temperature, constant load, and line operating conditions;
    5. The ground ring of the probe is pressed directly against the output ground of the power supply and the tip is in contact with the output voltage pin.
    6. Auto detected at power-up;